Taurus II Spike Spotlight – 12V – Black – IP56
lamps (purchase separately) and supplied with a plastic finned spike. Tempered glass lens. Locking knuckle mechanism to hold
the focus of the light and a deep glare shield to hide the light source from view, even close to path or patio.
finned ground spike resists accidental rotation in soil. Lens bezel twists off to allow lamp replacement.
may be achieved by using either the GLWJB IP68 junction box or GLWCC waterproof cable connector.
Lamp Colour (Kelvins)
The colour of a lamp is defined as a measurement called kelvins. A standard GLS light bulb in your house would be 2,700 kelvins
which is in the warm colour spectrum and a lamp with 5,000 kelvins would be at the very cold white spectrum.
12v Installation – See Instructions & Data Sheets Tab
Choosing the style of a product is only part of the equation you must also think of where that product will be used and
how it will be installed. All exterior lighting products on our web site have an IP rating appropriate to each light
fitting and its intended application and is therefore fit for purpose. Water ingress is the enemy for outdoor lighting
and the products supplied are only as good as the installation. The weakest point is always cable joints. All joints
must be made 100% watertight and this can be done using IP68 cable connectors and/or waterproof junction boxes which
are then filled with a re-enterable liquid gel mix. All joints where possible should be made above ground for easy
access and reduced water ingress. When installing ground buried lights adequate drainage systems should be put in
place especially in clay-based soil areas. If possible, use ground surface spike lights rather than a buried light.
Care must be taken with the cable runs and not to install transformers more than 30 metres away from the furthest
fitting to avoid any voltage drop. Cabling should be 2 core Rubber HO5RN-F or HO7RN-F and not PVC. PVC leads to capillary
action over time especially with UV degradation. Always check the correct type of transformer you need for your fittings.
We recommend wiring in parallel with Toroidal AC and LED DC drivers. But when using Milliamp mA LED drivers, they
should always be wired in series. Plug and Play kits are simply a case of daisy chaining the fittings via plug and
play junction boxes, connectors and extension cables using a 2-pin plug arrangement.
All exterior lights must be installed by a certified NIC EIC electrician and should be signed off by an electrician with
Part P certification. There are a selection of waterproof jointing kits and boxes available on this web site.






































Reviews
There are no reviews yet.