Manzi Outdoor Step And Brick Light – Warm White 3000k 240v Stainless Steel IP65 54 Lumens 3w
its 64° beam angle and mounted 500mm above the ground the fitting gives you a 2 metre radius of useful light, perfect for
lighting most paths and steps. The light is located by two spring clips on the body into the sleeve tube so that no external
screw fixings are visible
in a remote junction box.
| The plastic sleeve is built into the wall during construction or retrofitted into a hole cut with a coring bit the light pushes into the tube, where it is held firmly in place by spring clips, leaving a front plate with no visible fixing screws. Recess depth 81mm. Using a single RCD for large numbers of 240v fittings is not recommended due to the risk of nuisance tripping. We advise the use of separate RCD protection for each circuit and a maximum of 12 fittings per RCD. Where a garden lighting installation of more than 12 spike mount or recessed lights per circuit is proposed, we suggest the installation of 12v units with transformers, which results in a significantly higher fault tolerance and reliability in the total installation. |
Lamp Colour (Kelvins)
The colour of a lamp is defined as a measurement called kelvins. A standard GLS incandescent bulb in the home would be 2,700
kelvins which is in the warm colour spectrum and a lamp with 5,000 kelvins would be at the very cold white spectrum..
Installation 220- 240v – See Instructions & Data Sheets Tab
and diagram supplied.
Choosing the style of a product is only part of the equation you must also think of where that product will be used and
how it will be installed. All exterior lighting products on our web site have an IP rating appropriate to each light
fitting and its intended application and is therefore fit for purpose. Water ingress is the enemy for outdoor lighting
and the products supplied are only as good as the installation. The weakest point is always cable joints. All joints
must be made 100% watertight and this can be done using IP68 cable connectors and/or waterproof junction boxes which
are then filled with a re-enterable liquid gel mix. All joints where possible should be made above ground for easy
access and reduced water ingress. When installing ground buried lights adequate drainage systems should be put in
place especially in clay-based soil areas. If possible, use ground surface spike lights rather than a buried light.
Mains 240v cable will have less joints than a low voltage installation but care must be taken with the cable runs.
Cabling should be Rubber Butyl and not PVC. PVC leads to capillary action over time especially with UV degradation.
All exterior lights must be installed by a certified NIC EIC electrician and should be signed off by an electrician with
Part P certification. There are a selection of waterproof jointing kits and boxes available on this web site.
Using a single RCD for large numbers of 240v fittings is not recommended due to the risk of nuisance tripping. We advise
the use of separate RCD protection for each circuit and a maximum of 12 fittings per RCD. Always put outdoor lighting
on it’s own RCD. Where a garden lighting installation of more than 12 spike mount or recessed lights per circuit
is proposed, we suggest the installation of 12v units with transformers, which results in a significantly higher
fault tolerance and reliability in the total installation.